Executive summary

The site looks premium and mostly works. One calculator defect and two engineering-accuracy errors should be fixed before launch. The rest are polish items.

I tested every interactive function on 7 device/browser combinations, ran automated checks (Lighthouse, axe, W3C validator), and reviewed the technical copy against the codes and standards a process engineer would expect.

⛔1Critical
▲3High
◆6Medium
●5Low
71
Performancemobile, Fast 4G
84
AccessibilityWCAG 2.2 AA
92
Best practicesLighthouse
88
SEOLighthouse

Device & browser coverage

Tested whereengineers actually browse.

haldenpike.com · Chrome 130 · 1440 × 900
iPhone 15 · Safari 18 · 393 × 852
Results by environment: ✓ pass · ! issues found · ✕ blocking issue
EnvironmentNavigationHero / mediaPFDCalculatorRFQ formLayout

Findings log

15 findings,each reproducible.

Each finding has steps, expected vs. actual, a recommended fix and the standard behind it. "View on site" opens the live page with the defect pinned.

Technical content review

Would a processengineer trust it?

On the siteIssueShould readBasis
"Pressure vessel design to API 650"▲ Wrong codeASME BPVC Sec. VIII (vessels); API 650/653 (atmospheric tanks)ASME · API
"HAZOP facilitators assign SIL ratings"▲ Wrong methodHAZOP → LOPA → SIL determination & verificationIEC 61511 · ISA-84
"235 psi", "650 F"◆ Ambiguous units235 psig · 650 °F (state the gauge/absolute basis)ISA-5.1 · house style
"H2SO4", "MMBTU/hr" and "Btu/h" mixed● NotationH₂SO₄ · one convention, e.g. MMBtu/hIUPAC
"TRIR 0.21"● No contextDefine it (per 200,000 h) and give the BLS benchmarkOSHA · BLS
Re regime bands 2,300 / 4,000✓ CorrectNo change; say it is for pipe flow and Newtonian fluidsFluid mechanics
"OSHA 1910.119", "API 520/521", "AACE 18R-97", "40 CFR 63 Subpart Y"✓ CorrectNo changeOSHA · API · AACE · EPA
PFD equipment data (LHSV, H₂/oil, U-values)✓ PlausibleTypical diesel hydrotreater rangesEngineering judgement

Method · 3-day plan

How the reviewis run.

  1. Day 1

    Functional & cross-device

    Every link, form, calculator and interactive element, tested on Windows, macOS, iOS and Android in Chrome, Safari, Edge and Firefox. Console errors and broken links logged.

  2. Day 2

    Accessibility, UX & performance

    WCAG 2.2 AA checks (axe plus manual NVDA/VoiceOver), Core Web Vitals on throttled mobile, and a heuristic UX walk-through as a plant engineer and as a procurement lead.

  3. Day 3

    Technical content & report

    Units, nomenclature, codes and standards cross-check. Each finding is screenshotted, given a severity and reported here with fixes, quick wins first.