Technical content review
Would a processengineer trust it?
| On the site | Issue | Should read | Basis |
|---|---|---|---|
| "Pressure vessel design to API 650" | ▲ Wrong code | ASME BPVC Sec. VIII (vessels); API 650/653 (atmospheric tanks) | ASME · API |
| "HAZOP facilitators assign SIL ratings" | ▲ Wrong method | HAZOP → LOPA → SIL determination & verification | IEC 61511 · ISA-84 |
| "235 psi", "650 F" | ◆ Ambiguous units | 235 psig · 650 °F (state the gauge/absolute basis) | ISA-5.1 · house style |
| "H2SO4", "MMBTU/hr" and "Btu/h" mixed | ● Notation | H₂SO₄ · one convention, e.g. MMBtu/h | IUPAC |
| "TRIR 0.21" | ● No context | Define it (per 200,000 h) and give the BLS benchmark | OSHA · BLS |
| Re regime bands 2,300 / 4,000 | ✓ Correct | No change; say it is for pipe flow and Newtonian fluids | Fluid mechanics |
| "OSHA 1910.119", "API 520/521", "AACE 18R-97", "40 CFR 63 Subpart Y" | ✓ Correct | No change | OSHA · API · AACE · EPA |
| PFD equipment data (LHSV, H₂/oil, U-values) | ✓ Plausible | Typical diesel hydrotreater ranges | Engineering judgement |